Prooduct Name |
High Wind Speed Rain Test Chamber |
Prooduct Model |
HWR3600 |
Technical Parameters |
Product Attributes |
Working chamber dimensions(mm) |
1500×1600×1500(W×H×D) |
External dimensions(mm) |
4200×7520×2405(W×H×D) |
Rain Test |
Rainfall Intensity |
10~20 cm/h(The rainfall amount and rainfall intensity at the turntable can be adjusted.) |
Raindrop Diameter |
0.5mm~4.5mm |
Wind Speed Range |
5~18m/s(The horizontal wind speed at the center of the turntable air inlet and the raindrop angle shall be in accordance with the actual blowing conditions.) |
Rain Test Time |
It can be freely set within 0-999 minutes, automatically controlled, and can cycle periodically. |
Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
Rotary Worktable |
Dimensions: Φ800mm, and the rotation speed of the turntable can be adjusted. |
|
Load-bearing:≥65kg |
Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |
Dripping Rain Test |
Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
Drip Pan Area |
760×760mm,The height of the drip pan can be adjusted. |
Raindrop Diameter |
0.5mm~4.5mm,Aperture Spacing 25.4mm |
Water Drip Volume |
≥280±30L /㎡·h |
Rain Dripping Distance |
≥5 meters (to meet the raindrop velocity requirement of ≥9 m/s) |
Water Supply |
The water pump supplies water continuously, and the water level of the drip pan is controlled. |
Rain Dripping Time |
0~999min,Adjustable Configuration |
Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |
Waterproof Test |
Flushing Pressure |
≥276kPa |
Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
Nozzle |
Stainless steel material, grid-type top layout, with adjustable nozzle angles; a movable nozzle is arranged on the side. |
Number of Nozzles |
Within each 0.56 square meters of the surface area receiving rain, at least one nozzle shall be installed 450mm to 500mm away from the surface of the test specimen. |
Water Supply Mode |
The water pump supplies water continuously |
Test Time |
0~999min,Adjustable Configuration |
Raindrop Diameter |
2mm~4.5mm |
Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |